旋轉蒸發器 功能檢查規程

旋轉蒸發器功能檢查規程 
1 設備基本信息 
設備名稱:旋轉蒸發器 規格型號:RE52AA 
生產廠家:上海亞榮生化儀器廠 2 適用范圍 
本規程適用于旋轉蒸發器的周期性功能檢查。 
3 方法原理 
   通過控制電機,使燒瓶在適合速度下恒速旋轉,以增大蒸發面積;通過真空泵使蒸發燒瓶處于負壓狀態。蒸發燒瓶在旋轉同時置于水浴鍋中恒溫加熱,瓶內溶液在負壓下受熱擴散蒸發。 4 功能檢查項目及技術要求 
4.1 加熱功能:控溫范圍為室溫~99℃。 溫度波動性:±1℃;溫度均勻性:±1℃。 4.2 旋轉功能:可調節旋轉速度。 5 功能檢查條件    溫度:-10℃~40℃    濕度:≤90% 6  功能檢查方法及判別 
溫度波動性檢查:把儀器加熱溫度設定為60℃,在水浴鍋內幾何中心位置,用水銀溫度計(精度0.1℃)測量此點溫度,在30min內每隔3min測定一次溫度,共測定11次。 
溫度均勻性檢查:把儀器加熱溫度設定為60℃,在水浴鍋內兩個位置各放置一個水銀溫度計(精度0.1℃),計錄各點溫度,并計算**高值與**低值之差。 旋轉功能檢查:打開旋轉開關,設定一個旋轉速度,觀察燒瓶能否勻速旋轉。 對照技術要求。依據8.1結果判斷表,對儀器狀態進行判斷。 7 功能檢查周期 功能檢查周期定為一年。 8  功能檢查記錄及結果評述  